No heat new install, checked system off on ignition lock out due to loose wire, repaired and test ran, operation normal.

Near Indian Field Ct, Worton, MD 21678
Craig D.

Craig D.

Replaced flame safety sensor and voltage enhancement for exhaust removal system. Started system up. All systems running correct amps. Safety system working properly. System running correctly and in good order.

Near Lynch Rd, Worton, MD 21678
Craig D.

Craig D.

Indoor unit attic has a supply of 126 and a return of 79 wit a 47 delta. Visible ductwork looks good and the EZ trap was cleaned out. Voltage enhancement system read 12 with a factory setting of 12.5 and is within allowable fault. Blower wheel a little dirty, due to difficulty of cleaning wheel it'd be a level 2 cleaning, where the customer would only have to pay the difference in price as shown in cleaning estimate. Wheel spins without restriction and the bearing is tight. Board has no burn marks on it. Exhaust removal system spins without restriction and had an amp reading of 2.8 with a factory setting of 2.8. Cleaned burners and none of them looked distorted. Cleaned flame safety system and the ignitor looks fine. Filter looks ok, recommend customer checks at end of the month. Checked condensate line from both primary and secondary heat exchangers and they look fine. Ignition occurred with no problems with the flame being blue and no flames rolling back. Exterior of unit was wiped d

Near Drayton Landing Dr, Worton, MD 21678
Craig D.

Craig D.

Club Service. In cooling return temperature 77. and supply temperature 57 with a 20 degree temperature difference. Successfully ran gas warm air furnace through all stages of operation. Return temperature 78 degrees, warm supply temperature 109 degrees, total heat rise 31 degrees. customer. Draft motor amps were 2.9 to 3.1. Within a timely manner the gas ignited into a solid blue flame with no yellow tips. Cleaned flame sensor, cleaned all burners, brushed off control board, cleaned inside and outside cabinet with microfiber towel, and vacuumed throughout. Inspected blower motor wheel which looks ok and runs without restriction. Blower motor amps were 5.4, and its voltage enhancement system read 13.1 vs factory spec of 12.5 which means it is also within allowable fault. Tightened all screws, and electrical connections. Confirmed the uv bulb was working Furnace is in proper working order at this time.

Near Potts Rd, Worton, MD 21678
Paul N.

Paul N.

16 SEER 3.5 Ton AC and Furnace with new return drop and bypass humidifier

Near Indian Field Ct, Worton, MD 21678
Steven P.

Steven P.

Installing new Amana 16 SEER 3.5 Ton AC and Furnace with new return drop and bypass humidifier. All equipment is covered by a 10 year parts and 10 year labor warranty. The condenser and furnace are covered by a lifetime unit replacement warranty.

Near Indian Field Ct, Worton, MD 21678
Craig D.

Craig D.

Indoor unit has a supply of 67 with a return of 81 with a 14 delta. Voltage absorption system read 6.74 with a factory setting of 7.5 and is below allowable fault. The blower wheel spun without restriction and the bearing is tight. Cleaned indoor coil and the condensate line drained properly. Heat exchanger looks fine as does visible ductwork. Air filter looks good. Outdoor unit voltage absorption system read 5/22.8 with a factory setting of 5/40 and is below allowable fault. The FLA and RLA were good, cleaned outdoor unit and tightened the disconnect.

Near Big Woods Rd, Worton, MD 21678
Clay K.

Clay K.

Low cooling, test ran system, suction 130, liquid 310 with 8 deg sub-cool, compressor run load amps 15.4, actual 10.5, outdoor fan full load amps 2.8, actual 1.1, indoor air filter clean, 18 deg delta, no problems found, operation normal at htis time.

Near Still Pond Rd, Worton, MD 21678
Craig D.

Craig D.

Indoor unit has a supply of 57 and a return of 76 with a 19 delta. Condensate line looks clear and the ductwork has no visible compromises. Voltage absorption system read 19.9 with a factory setting of 20 and is within allowable fault. The blower compartment was dirty and cleaned, blower wheel looks good. Blower wheel spins without restriction and the bearing is tight. Coil looks good as does pan, recommend pan treatment to help keep coil clean. Heat exchanger looks good. Air filter changed customer supplied they have one extra left. Outdoor unit voltage absorption system read 4.9/40 with a factory setting of 5/40 and is within allowable fault. The FLA is 0.6 with a factory setting of 0.95 and the RLA is 5.4 with a factory setting of 12.8. Disconnect was tightened and outdoor unit cleaned.

Near Chinquapin Rd, Worton, MD 21678
Craig D.

Craig D.

See previous invoice.

Near Drayton Landing Dr, Worton, MD 21678
Craig D.

Craig D.

Indoor unit attic has a supply of 63 and a return of 79 with a 16 delta. The EZ trap was cleared and the air filter checked customer changed recently. Voltage absorption system read 12 with a factory setting of 12.5 and is within allowable fault. Blower wheel and compartment look good with the blower wheel spinning without restriction and the bearing is tight. Coil looks good as does pan, draining properly. Heat exchanger and ductwork both look good. Indoor unit garage has a supply of 57 and a return of 71 with a 14 delta. Voltage absorption system read 15.4 with a factory setting of 15 and is within allowable fault. Blower wheel spins without restriction and the bearing is tight. There was some sitting water in blower area and heat exchanger area from condensation. Heat exchangers look good as does ductwork. Coil was dirty and was cleaned, pan looked fine. Outside unit for second floor attic voltage absorption system read 4.9/33.2 which is below allowable fault. The FLA is 0.6 with a

Near Drayton Landing Dr, Worton, MD 21678
Craig D.

Craig D.

Indoor unit supply is 54 and return is 72 with a 18 delta. Coil looks good as does the pan. Couldnt see ductwork but the ductwork coming from unit looks good. Voltage absorption system read 12.9 with a factory setting of 12.5 and is within allowable fault. Blower is dirty, recommend it gets cleaned in fall. Blower spins without restriction and the bearing is tight. Unit had no air filter which is a 16x25x1, customer said they'd get. Heat exchanger looks good too. Outdoor unit voltage absorption system read 4.9/34.5 with a factory setting of 5/35 and is within allowable fault. The FLA is 0.6 with a factory setting of 1.3 and the RLA is 5 with a factory setting of 13.7. Outdoor unit cleaned and disconnect tightened.

Near Potts Rd, Worton, MD 21678
Clay K.

Clay K.

Club A/C service, checked indoor voltage absorption system and found within factory spec, 7.5 actual 7.1, test ran system and checked air filter, ok, checked outdoor system and found the voltage absorption system had failed, factory spec. 40/5 actual .9/4.9, replaced and test ran, compressor run load amps 13.0, actual 4.9, outdoor fan full load amps 1.3, actual 1.0, suction 66, liquid 170, operation normal at this time.

Near Possum Hollow Rd, Worton, MD 21678
Gerald T.

Gerald T.

Ten-year-old Trane heat pump (air handler in the attic). The outdoor ambient temp was approximately 53 degrees and the indoor dry bulb was 68. Removed the three dirty air filters (the customer didn't know about them) and told the customer to buy more. The cool supply air was 52 degrees and the room temperature return air was 67 degrees for a Delta T of 15. Measured .8 Amperes and 120 Volts on the air circulation system. Verified the circuit board and wiring were in good condition. Cleaned the indoor coil and added a pan treatment strip to help keep the coil pan clean. The electronic refrigerant leak detector test proved negative. Purged the condensation pipe and the water removal system's discharge tube with CO2, and added some descaler to prevent clogs. The refrigerant pumping system's run amps were 10.4 (RLA is 15.4), the start amps were 6.4, and the air exhaust system's amps were .8 (FLA is 2.8). Cleaned the electrical compartment and confirmed the defrost board, blades, disconnect,

Near Still Pond Rd, Worton, MD 21678
Gerald T.

Gerald T.

Ten-year-old Trane heat pump (air handler in the attic). The outdoor ambient temp was approximately 53 degrees and the indoor dry bulb was 68. Removed the three dirty air filters (the customer didn't know about them) and told the customer to buy more. The cool supply air was 52 degrees and the room temperature return air was 67 degrees for a Delta T of 15. Measured .8 Amperes and 120 Volts on the air circulation system. Verified the circuit board and wiring were in good condition. Cleaned the indoor coil and added a pan treatment strip to help keep the coil pan clean. The electronic refrigerant leak detector test proved negative. Purged the condensation pipe and the water removal system's discharge tube with CO2, and added some descaler to prevent clogs. The refrigerant pumping system's run amps were 10.4 (RLA is 15.4), the start amps were 6.4, and the air exhaust system's amps were .8 (FLA is 2.8). Cleaned the electrical compartment and confirmed the defrost board, blades, disconnect,

Near Still Pond Rd, Worton, MD 21678
Gerald T.

Gerald T.

Two-year-old air handler and condenser (AC only). The outdoor ambient temp was approximately 60 degrees and the indoor dry bulb was 67. Cleaned the EZ Trap safety sensor, and added some descaler to it and purged the condensate pipe with CO2 to prevent clogs. Replaced the Air Ranger filter insert with a new one and cleaned its metal frame. Confirmed the UV light was working. The cool supply air was 47 degrees and the room temperature return air was 64 degrees for a Delta T of 17. Measured 1.7 Amperes and 120 Volts on the air circulation system and its voltage enhancer had a correct uF charge. Verified the circuit board and wiring were in good condition. The indoor coil was clean. The refrigerant pumping system's run amps were 3.5 (RLA is 8), the start amps were 5.3, and the air exhaust system's amps were .5 (FLA is .7). Cleaned the electrical compartment and verified the blades, disconnect, wiring, and voltage distributor were in good condition. The latter had a normal 242 Volts across

Near Lynch Rd, Worton, MD 21678
Gerald T.

Gerald T.

Two-year-old air handler and condenser (AC only). The outdoor ambient temp was approximately 60 degrees and the indoor dry bulb was 67. Cleaned the EZ Trap safety sensor, and added some descaler to it and purged the condensate pipe with CO2 to prevent clogs. Replaced the Air Ranger filter insert with a new one and cleaned its metal frame. Confirmed the UV light was working. The cool supply air was 47 degrees and the room temperature return air was 64 degrees for a Delta T of 17. Measured 1.7 Amperes and 120 Volts on the air circulation system and its voltage enhancer had a correct uF charge. Verified the circuit board and wiring were in good condition. The indoor coil was clean. The refrigerant pumping system's run amps were 3.5 (RLA is 8), the start amps were 5.3, and the air exhaust system's amps were .5 (FLA is .7). Cleaned the electrical compartment and verified the blades, disconnect, wiring, and voltage distributor were in good condition. The latter had a normal 242 Volts across

Near Lynch Rd, Worton, MD 21678
Gerald T.

Gerald T.

The air handler was only off due to a loose wire to the neutral on the IFC. After tightening it it immediately started.

Near Still Pond Rd, Worton, MD 21678
Gerald T.

Gerald T.

The air handler was only off due to a loose wire to the neutral on the IFC. After tightening it it immediately started.

Near Still Pond Rd, Worton, MD 21678
Paul N.

Paul N.

Oil boiler-??? ??? ??? 1.00 80W Cleaned heat exchanger. Replaced nozzle and oil filter. Adjusted electrodes and burner. Performed bronze level voltage enhancement system renovation on air handlers. Air handler-Trane 4TEE3F37B1000AA SN: 9422P0J1V Heat pump-Trane 4TWX5036A1000AA SN: 10261T0S2F System rejuvenation. Coils and blower wheel are clean. Air circulation system motor amperage within specifications. Temperature rise 22 degrees. Tested operation of auxiliary heat. System pressures/temperatures within specifications. System in good condition and working properly. Air handler-Daikin FVXS18NVJU SN: C001839 Air handler-Daikin FTXS09LVJU SN: E076876 Air handler-Daikin FTXS09LVJU SN: E076972 Air handler-Daikin FTXS12LVJU SN: E091031 Heat pump-Daikin 4MXS36RMVJU SN: G005235 Tested operation of air handlers. Checked/cleaned filters. Checked operation of heat pump. System in good condition and working properly at this time.

Near Still Pond Rd, Worton, MD 21678
Gerald T.

Gerald T.

10-year-old upside down conterflow propane furnace in the garage for the first floor. Removed the very dirty air filter and told the customer to buy more. It hadn't been replaced since I was here in April 2017. Replaced the humidifier filter pad. The warm supply air was 106 degrees and the room temperature return air was 68 degrees for a Delta T of 38. This is within the manufacturer's recommended rating. Measured 2.9 Amperes and 120 Volts on the combustion exhaust system, 24 Volts on the barometric sensor and fuel distribution system, .4 Amperes and 120 Volts on the ignition system (didn't see any chips or cracks to soon cause a failure), and approximately four Amperes and 120 Volts on the air circulation system. The latter's new voltage enhancer had a correct uF charge. Cleaned the burner tubes and the burner and air circulation compartments. The fins on the latter are starting to accrue too much caked-on dirt and dust. A blower cleaning will be needed in the next couple of years. Ca

Near Drayton Landing Dr, Worton, MD 21678
Gerald T.

Gerald T.

10-year-old upside down conterflow propane furnace in the garage for the first floor. Removed the very dirty air filter and told the customer to buy more. It hadn't been replaced since I was here in April 2017. Replaced the humidifier filter pad. The warm supply air was 106 degrees and the room temperature return air was 68 degrees for a Delta T of 38. This is within the manufacturer's recommended rating. Measured 2.9 Amperes and 120 Volts on the combustion exhaust system, 24 Volts on the barometric sensor and fuel distribution system, .4 Amperes and 120 Volts on the ignition system (didn't see any chips or cracks to soon cause a failure), and approximately four Amperes and 120 Volts on the air circulation system. The latter's new voltage enhancer had a correct uF charge. Cleaned the burner tubes and the burner and air circulation compartments. The fins on the latter are starting to accrue too much caked-on dirt and dust. A blower cleaning will be needed in the next couple of years. Ca

Near Drayton Landing Dr, Worton, MD 21678
John A.

John A.

New air conditioner and air handler

Near Lynch Rd, Worton, MD 21678
Sean D.

Sean D.

Completed club ac inspection on Amana air conditioning.

Near Drayton Landing Dr, Worton, MD 21678
Sean D.

Sean D.

Checking water leak on a Slant Fin oil fired boiled.

Near St James Newtown Rd, Worton, MD 21678