Map of Charlestown, MD

Awesome representative




Review of Moon Air Inc.

Great


Craig D.

Craig D.

Customer has 16 registers/returns, there might be a 17th one in the kitchen couldn't find.

Near Caroline St, Charlestown, MD 21914
Gerald T.

Gerald T.

Nine-year-old Amana propane furnace and 25-year-old Lennox condenser. Checked the air filter and it didn't need to be replaced. The outdoor ambient temp was approximately 63 degrees, the indoor dry bulb was 69, the indoor wet bulb was 59, and the relative humidity was 53%. The cool supply air was 53 and the room temperature return air was 68 for a Delta T of 15. Based on these readings the supply air temp is excellent. Measured 5.65 Amperes on the air circulation system, its new voltage enhancer had a correct uF charge, and verified its compartment was clean with no black growth developing, and the circuit board and wiring were in good condition. Purged the condensation pipe and the water removal system's (confirmed it was working) discharge tube with CO2 (and added some descaler to it) to prevent clogs. The refrigerant pumping system's run amps were 13.1 (RLA is 16) too high)), the start amps were 5.7, and the air exhaust system's amps were .55 (FLA is 1). A resistance check on these

Near S Ogle St, Charlestown, MD 21914
Gerald T.

Gerald T.

Nine-year-old Amana propane furnace and 25-year-old Lennox condenser. Checked the air filter and it didn't need to be replaced. The outdoor ambient temp was approximately 63 degrees, the indoor dry bulb was 69, the indoor wet bulb was 59, and the relative humidity was 53%. The cool supply air was 53 and the room temperature return air was 68 for a Delta T of 15. Based on these readings the supply air temp is excellent. Measured 5.65 Amperes on the air circulation system, its new voltage enhancer had a correct uF charge, and verified its compartment was clean with no black growth developing, and the circuit board and wiring were in good condition. Purged the condensation pipe and the water removal system's (confirmed it was working) discharge tube with CO2 (and added some descaler to it) to prevent clogs. The refrigerant pumping system's run amps were 13.1 (RLA is 16) too high)), the start amps were 5.7, and the air exhaust system's amps were .55 (FLA is 1). A resistance check on these

Near S Ogle St, Charlestown, MD 21914
Gerald T.

Gerald T.

13-year-old Amana propane furnace and Goodman condenser. Checked the air fliter and it didn't need to be replaced. The outdoor ambient temp was approximately 62 degrees, the indoor dry bulb was 67, the indoor wet bulb was 57, and the relative humidity was 56%. The cool supply air was 52 and the room temperature return air was 68 for a Delta T of 16. Based on these readings the supply air temp is excellent. Measured 8.4 Amperes on the air circulation system, its voltage enhancer that was failing this fall is now below the manufacturer's recommended rating and should be replaced ASAP. Verified its compartment was clean with no black growth developing, and the circuit board and wiring were in good condition. Confirmed the indoor coil was clean but its coil pan has a lot of rust build-up. It needs a pan treatment strip. Purged the condensation pipe (cleaned its U trap) and the water removal system's discharge tube with CO2 (and added some descaler to it) to prevent clogs. There is some wat

Near S Ogle St, Charlestown, MD 21914
Gerald T.

Gerald T.

13-year-old Amana propane furnace and Goodman condenser. Checked the air fliter and it didn't need to be replaced. The outdoor ambient temp was approximately 62 degrees, the indoor dry bulb was 67, the indoor wet bulb was 57, and the relative humidity was 56%. The cool supply air was 52 and the room temperature return air was 68 for a Delta T of 16. Based on these readings the supply air temp is excellent. Measured 8.4 Amperes on the air circulation system, its voltage enhancer that was failing this fall is now below the manufacturer's recommended rating and should be replaced ASAP. Verified its compartment was clean with no black growth developing, and the circuit board and wiring were in good condition. Confirmed the indoor coil was clean but its coil pan has a lot of rust build-up. It needs a pan treatment strip. Purged the condensation pipe (cleaned its U trap) and the water removal system's discharge tube with CO2 (and added some descaler to it) to prevent clogs. There is some wat

Near S Ogle St, Charlestown, MD 21914
Clay K.

Clay K.

A/C repair and service

Near Conestoga St, Charlestown, MD 21914
Steve M.

Steve M.

Checked out a forced air gas furnace with ac Will replace with 16 seer 2 stage Amana system in one day

Near Water St, Charlestown, MD 21914
Sean D.

Sean D.

replaced worn dual capacitor on Amana condenser.

Near S Ogle St, Charlestown, MD 21914
Sean D.

Sean D.

replaced defective contactor on Lennox condenser.

Near Ogle St, Charlestown, MD 21914
Steve M.

Steve M.

Servicing a geothermal water to air heat pump

Near Water St, Charlestown, MD 21914
Bill M.

Bill M.

Moon Electric is in Charlestown installing tamper resistant gfci receptacles.

Near Bladen St, Charlestown, MD 21914
Chris S.

Chris S.

Service call on a Goodman furnace heating system. Found that the inducer assembly was damaged and heat exchanger ruptured. Made necessary heating repairs to the inducer in heat exchanger cycled unit running properly upon completion.