Moon Air provides fast, reliable air conditioning, heating, and electrical services to the residents of West Chester, PA and the surrounding areas!

We pride ourselves on a high standard of customer service. Read our reviews and find out why your neighbors consider us to be their preferred HVAC company and electrician in West Chester, PA.

Local Reviews
for West Chester, PA

Moon Air Inc. Rated 5.0 out of 5 stars based on 2 customer reviews


Map of West Chester, PA

Furnace repair




Review of Moon Air Inc.

Furnace repair, great service and friendly technician!


Map of West Chester, PA

Great service!




Review of Moon Air Inc.

Clay was very professional and thorough. He explained everything so that I fully understood. He also gave suggestions on how to save on our electric bill!!!


Clay K.

Clay K.

Club renewal

Near Macroom Ave, West Chester, PA 19382
Clay K.

Clay K.

System service, test ran system, voltage enhancement system factory spec 70, actual 69.9, compressor run load amps factory spec 21.8, actual 11.6, outdoor fan full load amps factory spec 2.8, actual 1.1, start up amps 24.3, installed compressor saver system and now start up amps 8.4, delta t 18, operation normal at this time.

Near Macroom Ave, West Chester, PA 19382
Greg H.

Greg H.

Ac club service getting a 18 degree delta t. Filter is clean. Checked condesate drain and did not detect any clogs. Checked uv light and it is still working. Tighten all screws and eletrical connections. Checked blower, evaporator, and pan all are clean. Checked blower voltage enhancement system and it read within factory spec of 15uf. Checked duct work and there is no debris. Checked outdoor system coil is clean Voltage enhancement system read within factory spec. Voltage gateway haves no pitting. Operation normal at this time

Near Macroom Ave, West Chester, PA 19382
Clay K.

Clay K.

Not a call back during installation power wire for thermostat was Nick at the terminal board for the furnace and finally broke repaired that wire and checked all others operation normal at this time.

Near Macroom Ave, West Chester, PA 19382
Clay K.

Clay K.

Club service Heating checked manifold gas pressure 3.3 in WC clean air ranger screen air ranger filter clean operation normal at this time.

Near Macroom Ave, West Chester, PA 19382
Clay K.

Clay K.

No heat, system control blank, checked equipment and found that the low voltage protection system had failed due to a shorted power supply cord for the electrostatic filter, installed replacement protestion system and also new power cord, test ran. \

Near Macroom Ave, West Chester, PA 19382
Paul N.

Paul N.

16 SEER 5 Ton AC

Near Macroom Ave, West Chester, PA 19382
Steven P.

Steven P.

Installing new Amana 16 SEER 5 Ton AC with Honeywell Lyric wifi thermostat and 10 year parts, 10 year labor, and lifetime unit replacement warranty

Near Macroom Ave, West Chester, PA 19382
Gerald T.

Gerald T.

Nine-year-old furnace, indoor coil, and outdoor coil. Indoor dry bulb was 66. The system immediately started (fan) upon arrival. However, the cool supply air was 66 degrees and the return was also 66. The air filter was new. The indoor coil was only a little dirty but found numerous refrigerant leaks with the electronic refrigerant leak detector. Outside the refrigerant pumping system's run amps were zero. Tested the voltage enhancer and it was at 0 uF. Replaced the voltage enhancer with the tenant's permission. Thereafter the refrigerant pumping system's run amps were 10 (FLA is 20), the start amps were 6.5, and the air exhaust system's amps were .65 (FLA is 1.5). All normal after the repairs. The supply temp fell to 58, but the liquid pressure was 205 and the liquid line temp was 68 for a SC of two. The vapor pressure was 70 and the vapor line temp was 63 for a SH of 49. These readings indicate the system is low on refrigerant due to several leaks on the indoor coil. Sending an estim

Near S Bolmar St, West Chester, PA 19382
Gerald T.

Gerald T.

Nine-year-old furnace, indoor coil, and outdoor coil. Indoor dry bulb was 66. The system immediately started (fan) upon arrival. However, the cool supply air was 66 degrees and the return was also 66. The air filter was new. The indoor coil was only a little dirty but found numerous refrigerant leaks with the electronic refrigerant leak detector. Outside the refrigerant pumping system's run amps were zero. Tested the voltage enhancer and it was at 0 uF. Replaced the voltage enhancer with the tenant's permission. Thereafter the refrigerant pumping system's run amps were 10 (FLA is 20), the start amps were 6.5, and the air exhaust system's amps were .65 (FLA is 1.5). All normal after the repairs. The supply temp fell to 58, but the liquid pressure was 205 and the liquid line temp was 68 for a SC of two. The vapor pressure was 70 and the vapor line temp was 63 for a SH of 49. These readings indicate the system is low on refrigerant due to several leaks on the indoor coil. Sending an estim

Near S Bolmar St, West Chester, PA 19382
Clay K.

Clay K.

Furnace repair.

Near Cherry Farm Ln, West Chester, PA 19382