Moon Air provides fast, reliable air conditioning, heating, and electrical services to the residents of Still Pond, MD and the surrounding areas!

We pride ourselves on a high standard of customer service. Read our reviews and find out why your neighbors consider us to be their preferred HVAC company and electrician in Still Pond, MD.

Local Reviews
for Still Pond, MD

Moon Air Inc. Rated 5.0 out of 5 stars based on 1 customer reviews


Map of Still Pond, MD

Great




Review of Moon Air Inc.

Always satisfied with Moon.


Clay K.

Clay K.

No A/C outdoor system dose not run, checked system and found to be in lockout due to locked rotor amps, installed start assist, rest ran.

Near Rosedale Cannery Rd, Still Pond, MD 21667
Craig D.

Craig D.

Cooling Rejuvenation x 5 Outdoor unit foyer/living room voltage enhancement system read 5/45 with a factory setting of 5/45. FLA 0.6 and RLA 6.5. Cleaned coil and exterior, interior drain holes clear. Checked disconnect for safety and wiring connections. System normal operation at this time. Outdoor unit office/den voltage enhancement system read 5/44 with a factory setting of 5/45. FLA 0.55 and RLA 5.8. Cleaned coil and exterior, interior drain holes clear. Checked disconnect and wiring connections for safety. System normal operation at this time. Indoor unit foyer/living room supply 55 with a 71 return and 16 delta. Static pressure is fine. Blower spins without restriction. Coil looks fine both sides. Treated drain line with cleaner. Wire and connections are good. Indoor unit office/den has a supply of 48 with a 72 return and 24 delta. Static pressure is fine. Voltage enhancement system read 4.9 with a factory setting of 5. Condensate pump constantly running while servicing syste

Near Still Pond Rd, Still Pond, MD 21667
Clay K.

Clay K.

Purge air from LP line

Near Still Pond Rd, Still Pond, MD 21667
Clay K.

Clay K.

Returned and Installed ourdoor warm weather shut down system, set to 70 degrees, above that temperature the boiler will shut off.

Near Still Pond Rd, Still Pond, MD 21667
Clay K.

Clay K.

Returned and replace two zone control system, pumping system and fill valve, purge air from system. Checked for flow issue on both zones, found that the thermostatic mixing element has failed, removed element so forward can be established for zones.

Near Still Pond Rd, Still Pond, MD 21667
Clay K.

Clay K.

No heat, hydronic system air bound, purge air from system, one zone valve has leaked (see photo) pressure temperature guage is leaking cannot see temperature or pressure (see photo), recommend replacement of both zone valves and also pressure temperature guage.

Near Still Pond Rd, Still Pond, MD 21667
Clay K.

Clay K.

Low heat output kitchen system, hydronic coil with variable speed air handler, changed to a lower fan speed test ran.

Near Still Pond Rd, Still Pond, MD 21667
Craig D.

Craig D.

Heating Rejuvenation x 4 Indoor unit kitchen has a supply of 80 with a 67 return. Checked wire connections and board all looks good. Blower amps 2.03. Blower wheel looks fine. Indoor unit living room has a supply of 83 with a 65 return and 18 delta. The blower amps read 0.7. Blower wheel clean and spins without restriction. Outdoor unit attic voltage enhancement system read 5/39.8 with a factory setting of 5/40 and is within allowable fault. Indoor unit attic has a 160 supply and a 88 return with a 72 delta. Blower amps read 1.3 and heat strip amps were 20.2. Cleaned blower wheel and blower compartment. Wheel spins without restriction. Electrical connections look good and are tight. Cleaned exterior, system normal operation at this time. Indoor unit den has a supply of 124 and a return of 76 with a 48 heat rise. Cleaned dirty blower, spins without restriction and the bearing is tight. Exhaust removal system read 2.9uf with a factory setting of 3uf. Blower voltage enhancement syst

Near Still Pond Rd, Still Pond, MD 21667
Paul N.

Paul N.

Installed new thermostats for kitchen unit and master bedroom. When troubleshooting kitchen thermostat had to turn AC off at disconnect. Disconnect breaker failed after turning off, informed customer and performed repair on disconnect. Test ran both systems with new thermostats in heating and cooling. Kitchen thermostat works fine, electric heat comes on with cooling on master bedroom thermostat, need to bring replacement. Indoor unit master bedroom has a supply of 96 and a 73 return with a 26 delta. Blower amp reading 0.9 and heat strip amp reading 20. Cleaned blower and blower cabinet area. Connections are tight and no burn marks. Vacuumed air filter. Cleaned exterior of unit. Need to come back with new T6 thermostat.

Near Still Pond Rd, Still Pond, MD 21667
Paul N.

Paul N.

Install existing furnace in garage

Near Rosedale Cannery Rd, Still Pond, MD 21667
Craig D.

Craig D.

Outdoor unit living room voltage enhancement system read 5/45.8 with a factory setting of 5/45 and is within allowable fault. Cleaned out interior, exterior and coil. Checked disconnect for safety and system normal operation at this time. Outdoor unit office voltage enhancement system read 5/44.7 with a factory setting of 5/45 and is within allowable fault. Cleaned coil, exterior and interior. Checked disconnect for safety and system normal operation at this time. Outdoor unit attic voltage enhancement system read 5/35 with a factory setting of 5/35. Wire going from voltage enhancement system to gateway has damaged connectors on either end. Repaired connections and insulated to prevent electrical issues. Cleaned out interior debris so drain holes are clear, cleaned coil and exterior. Checked disconnect for safety and system normal operation at this time. Outdoor unit kitchen voltage enhancement system read 5/34.5 with a factory setting of 5/35 and is within allowable fault. Found de

Near Still Pond Rd, Still Pond, MD 21667
Craig D.

Craig D.

Found system low on charge and also found defective water safety switch for aux drain pan. Couldnt find leak with electronic leak detector, added dye and brought refrigerant charge up to normal. Need to return at some point to locate leak. Customer has a extended warranty through trane that we need to look into if we make any repairs.

Near Still Pond Rd, Still Pond, MD 21667
Paul N.

Paul N.

Silver level furnace and AC

Near Rosedale Cannery Rd, Still Pond, MD 21667
Steven P.

Steven P.

Installing silver level furnace and AC system with 10 year parts, 10 year labor and lifetime unit replacement warranty. Customer swapping moisture control system with surgical quality air filtration because the system is in the attic. Scheduled install for Friday 5/29

Near Rosedale Cannery Rd, Still Pond, MD 21667
Clay K.

Clay K.

No heat, kitchen area, checked system and found that the Tace Zone Valve Power Head failed, did not open the flow control for that area, installed replacement and test ran, operation normal at this.

Near Still Pond Rd, Still Pond, MD 21667
Craig D.

Craig D.

The indoor furnace for office and master bedroom has a supply of 125 and a 76 return with a 49 delta in heating. Voltage enhancement system read 3.8 with a factory setting of 5 and is below allowable fault. Air filter is dirty, recommend it gets replaced. Blower wheel spins without restriction and the bearing is tight. Don't see any burn marks on board and connections are tight. Voltage enhancement system on exhaust removal system read 2.85 with a factory setting of 3 and is within allowable fault. Cleaned burners and the flame safety system, both had no distortions. The flame ignitor looked good too. Ignition occurred with no problems with the flame being blue and no flames rolling back. Wiped down exterior unit. Indoor unit kitchen had a supply of 90 and a return of 73 with a 17 delta in heating. There were no burn marks on the board and the wires were fine. The blower spins without restriction and the bearing is tight. Cleaned the blower wheel and cage, recommend a blower cleaning

Near Still Pond Rd, Still Pond, MD 21667
Gerald T.

Gerald T.

Five AC rejuvenations. Outside air temp was approximately in the high 30s defrees Fahrenheit. 13-year-old Bryant propane furnace with one-year-old Amana coils for pool table and office room. The air filter didn't need to be replaced. The cool supply air was 46 degrees and the room temperature return air was 67 degrees for a Delta T of 21. Didn't detect any leaks in the indoor coil and measured normal Amperes on the air circulation system and its voltage enhancer had a correct uF charge. The indoor coil was clean. Purged the condensation pump's discharge tube with CO2 to prevent clogs, and cleaned the air circulation compartment. Verified the circuit board and wiring were in good condition. The refrigerant pumping system's run amps were 6.5 (RLA is 15), the start amps were 6.6, and the air exhaust system's amps were .5 (FLA is. 95). Its wiring and voltage distributor (normal 244 volts through it) were in good condition, and its voltage enhancer also had a correct uF charge. The discha

Near Still Pond Rd, Still Pond, MD 21667
Gerald T.

Gerald T.

Five AC rejuvenations. Outside air temp was approximately in the high 30s defrees Fahrenheit. 13-year-old Bryant propane furnace with one-year-old Amana coils for pool table and office room. The air filter didn't need to be replaced. The cool supply air was 46 degrees and the room temperature return air was 67 degrees for a Delta T of 21. Didn't detect any leaks in the indoor coil and measured normal Amperes on the air circulation system and its voltage enhancer had a correct uF charge. The indoor coil was clean. Purged the condensation pump's discharge tube with CO2 to prevent clogs, and cleaned the air circulation compartment. Verified the circuit board and wiring were in good condition. The refrigerant pumping system's run amps were 6.5 (RLA is 15), the start amps were 6.6, and the air exhaust system's amps were .5 (FLA is. 95). Its wiring and voltage distributor (normal 244 volts through it) were in good condition, and its voltage enhancer also had a correct uF charge. The discha

Near Still Pond Rd, Still Pond, MD 21667
Gerald T.

Gerald T.

13-year-old Bryant propane furnace with Amana Condenser for pool table and office room. Replaced the dirty air filter with one provided by the customer. The air circulation system correctly started approximately one minute after the flames ignited. The warm supply air was 108 degrees and the room temperature return air was 64 degrees for a Delta T of 44. This is within the manufacturer's recommended rating. Measured .5 Amperes and 120 Volts on the combustion exhaust system (its voltage enhancer had a correct uF charge), 24 Volts on the barometric sensor and fuel distribution system, .5 Amperes and 120 Volts on the ignition system (didn't detect any beginning chips or cracks), and four Amperes on the air circulation system (its voltage enhancer had a correct uF charge). Purged the flue condensation tubing and the condensation pump's discharge tube with CO2 to prevent clogs. Cleaned the burner tubes and their wings and the burner and air circulation compartments. The limit, rectification

Near Still Pond Rd, Still Pond, MD 21667
Gerald T.

Gerald T.

13-year-old Bryant propane furnace with Amana Condenser for pool table and office room. Replaced the dirty air filter with one provided by the customer. The air circulation system correctly started approximately one minute after the flames ignited. The warm supply air was 108 degrees and the room temperature return air was 64 degrees for a Delta T of 44. This is within the manufacturer's recommended rating. Measured .5 Amperes and 120 Volts on the combustion exhaust system (its voltage enhancer had a correct uF charge), 24 Volts on the barometric sensor and fuel distribution system, .5 Amperes and 120 Volts on the ignition system (didn't detect any beginning chips or cracks), and four Amperes on the air circulation system (its voltage enhancer had a correct uF charge). Purged the flue condensation tubing and the condensation pump's discharge tube with CO2 to prevent clogs. Cleaned the burner tubes and their wings and the burner and air circulation compartments. The limit, rectification

Near Still Pond Rd, Still Pond, MD 21667
Paul N.

Paul N.

Inspection of Quiets idea high efficiency gasboiler.

Near MD-292, Still Pond, MD 21667
Paul N.

Paul N.

Inspection/tune up on Daikin heat pump and Navien high efficiency gas boiler.

Near MD-292, Still Pond, MD 21667
Chris S.

Chris S.

• Performing Ac Repairs on a Samsung mini split system that has iced up for one of our valued commercial hvac maintenance agreement customers.

Near Still Pond Rd, Still Pond, MD 21667
Chris S.

Chris S.

• Performed heating system maintenance on two heat pump systems. Replaced the air handler for the Bryant System with a Amana air handler that has a 10 year parts warranty.

Near Maple Ave, Still Pond, MD 21667
Chris S.

Chris S.

Installing a new Maytag condenser and matching coil to replace a 15 year old Rheem unit that had a failed compressor for a residential HVAC maintenance agreement customer in the Northwest part of town near Silverstone golf course.

Near Still Pond Rd, Still Pond, MD 21667