Moon Air provides fast, reliable air conditioning, heating, and electrical services to the residents of Millington, MD and the surrounding areas!

We pride ourselves on a high standard of customer service. Read our reviews and find out why your neighbors consider us to be their preferred HVAC company and electrician in Millington, MD.

Local Reviews
for Millington, MD

Moon Air Inc. Rated 5.0 out of 5 stars based on 11 customer reviews


Map of Millington, MD

Great Service




Review of Moon Air Inc.

Found the problem to fix our air conditioner. Scheduled electrician to fix other problems with the breakers.


Map of Millington, MD

AC INSTALL




Review of Moon Air Inc.

excellent and professional


Map of Millington, MD

Thank you!!!




Review of Moon Air Inc.

Many Thanks to Jeff for coming to our home to check the filter size for our HVAC system and delivering the correct size! Jeff is very professional and friendly!!


Map of Millington, MD

Absolutely the best service ever




Review of Moon Air Inc.

Excellent.


Map of Millington, MD

Excellent technician




Review of Moon Air Inc.

Jeff was very friendly and knowledgeable about his work!We thank him very much!


Map of Millington, MD

Great Service




Review of Moon Air Inc.

Craig D. was very thorough and explained exactly what he was doing and shared pictures upon completion. Great job!


Map of Millington, MD

Great Service




Review of Moon Air Inc.

Our technician AJ was very friendly and professional during her visit. She explained everything that she did to complete the service agreement work on our heat pumps. Thank you !!


Map of Millington, MD

Great Service




Review of Moon Air Inc.


Map of Millington, MD

Professional and friendly




Review of Moon Air Inc.

Clay and Derick were professional, friendly and honest ! I'm extremely pleased with the service we received. CoCo our dog loved both technicians. Thank you


Map of Millington, MD

Professional, responsible, knowledgeable and honest!




Review of Moon Air Inc.

Clay and his assistant were professional and reliable. I appreciated the knowledge regarding my unit and the honesty regarding the condition and life expectancy of the equipment. No hard sell or attempt to push me in any direction or decision. Excellent technicians. I will refer Moon to others.


Great Service and knowledgable personnel !




Review of Moon Air Inc.

The service rep was fast ,friendly and competent!


Keith F.

Keith F.

Was a little more than they anticipated. They will call me this afternoon with a decission.

Near Kent Mill Dr, Millington, MD 21651
Joe E.

Joe E.

Replace 200 amp panel recessed in garage wall with new.

Near Blanco Rd, Millington, MD 21651
Clay K.

Clay K.

Follow up from Greg, checked system and found no line voltage to outdoor system, checked panel (T&B) and found that the breaker for the unit had failed, 30 amp, had to replace with 20 amp for now, 60 amp breaker for air handler is also damaged along with the main bus bar, need to schedule our electrician to survey the panel and make nessary repairs.

Near Blanco Rd, Millington, MD 21651
Paul N.

Paul N.

3.5 ton 16 seer Amana ac renovation. 25' line set. Furnace is 18x35x29 deep Coil is 22x21 Supply 22x21

Near Dogwood Ct, Millington, MD 21651
Jeffery A.

Jeffery A.

Two System A/C Rejuvenation Preformed Inspected indoor units Under home unit : Electrical components and safety controls are working properly, return grill and plenum are clean, filters clean, evaporator coil is clean, blower is clean , supply and return is clean Attic unit : Electrical components and safety controls are working properly, return grill and plenum are clean, filters clean, evaporator coil is clean, blower is clean , supply and return is clean. 7.5cap was reading out of recommendation range. Replaced with new 7.5cap. Retested all electrical components. All amperage and voltage was within recommended range Ducts are properly installed and secure Inspected outdoor units Big Condenser : Electrical Components are working properly, refrigerant pressures good. Cleaned cabinet and washed out coil. Small Condenser : Electrical Components are working properly, refrigerant pressures good. Cleaned cabinet and washed out coil. 30/5cap was reading 26/4. Replaced with new 30

Near Chester River Heights Rd, Millington, MD 21651
Jeffery A.

Jeffery A.

A/C Rejuvenation Preformed Inspected indoor unit, Electrical components and safety controls are working properly, return grill and plenum are clean, filters clean, evaporator coil is clean, blower is clean , supply and return is clean. All electrical components are within range Ducts are properly installed and secure Inspected outdoor unit. Electrical Components are working properly, refrigerant pressures good. Cleaned cabinet and washed out coil. All electrical components are within recommended range. Refrigerant levels are good. SH/SC is within recommended range Signed homeowner up for gold membership Unit is properly cooling at this point in time

Near Spring Rd, Millington, MD 21651
Jeffery A.

Jeffery A.

Dropped off proper filters, homeowners needed 20x20 mpg filter

Near Fords Landing Ln, Millington, MD 21651
Jeffery A.

Jeffery A.

Two System A/C Rejuvenation Preformed Inspected indoor unit, Electrical components and safety controls are working properly, return grill and plenum are clean, filters clean, evaporator coil is clean, blower is clean , supply and return is clean Ducts are properly installed and secure Inspected outdoor unit. Electrical Components are working properly, refrigerant pressures good. Cleaned cabinet and washed out coil. Provided homeowners with requested filters Unit is properly cooling at this point in time

Near Fords Landing Ln, Millington, MD 21651
Jeffery A.

Jeffery A.

Conducted AC inspection Inspected indoor and outdoor unit for cleanliness, loose wiring and failed components. Inspected unit for correct specs. No faults found on unit Unit is running properly at this moment

Near Sassafras St, Millington, MD 21651
Craig D.

Craig D.

Heating Rejuvenation Indoor unit has a supply of 115 with a 77 return and 38 heat rise. Static pressure supply is 0.16 and return is -0.34. Aprilaire air cleaner not working on arrival, vacuumed metal grate and plugged power head into a socket that is working. Recommended air ranger install if homeowner wants an air cleaner or at least use a 16x25x4 air filter. Checked heat exchanger for safety. Tested gas shut off on fuel delivery system and gas line. Cleaned blower wheel and compartment. Voltage enhancement system read 24.6 with a factory setting of 25 and is within allowable fault. Voltage enhancement system for exhaust removal system read 4.9 with a factory setting of 5 and is within allowable fault. Exhaust removal amps were 0.8 and blower amps 5.1. Vacuumed and cleaned burner and furnace area. Flame sensing system read 1.4uA before cleaning and 2.8uA after. Cleaned exterior of furnace. System normal operation at this time.

Near Dogwood Ct, Millington, MD 21651
Greg H.

Greg H.

Getting a 40 degree split Checked blower getting 6.2 amps. Checked evaporator it looks clean. Checked all eletrical connections operation normal at this time

Near Legion Rd, Millington, MD 21651
Ashley  J.

Ashley J.

Delta t 46 Voltage enhancement system 7.6 in factory spects Air circulation system is clean Sensor 10.4 Base.60 Igniter .40 Air circulation 4.4 System was wiped down Delta t 36 Filter was clean Air circulation system was cleaned Voltage enhancement system 6.2 below factory spects Base .90 Igniter 3.7 Sensor 14 Air circulation system 2.8 System was wiped down Everything is in factory spects at this time besides Voltage enhancement system for the attic

Near Chester River Heights Rd, Millington, MD 21651
Ashley  J.

Ashley J.

Attic heat pump Amps .79 Delta t 12 Air circulation system is clean Rla 4.5 Fla .7 Voltage enhancement system 34.6/5 Basement heat pump Air circulation system is clean Amps1.8 Delta t 10 Rla 5 Common 1.8 Voltage enhancement system 35/5

Near Fords Landing Ln, Millington, MD 21651
Craig D.

Craig D.

Replaced uv bulb, started and tested, working normally at this time.

Near Big Stone Rd, Millington, MD 21651
Greg H.

Greg H.

Did club oil service changed nozzle 65. 80a, and changed filter. Did wd40 wipe down. Cleaned and adjusted electrodes. Bleed air out of system did smoke test. Checked blower wheel. Checked blower capacitor, Checked all eletrical connections operation normal at this time

Near Dudley Corner Rd, Millington, MD 21651
Craig D.

Craig D.

Cleaned and checked heatpump system in both a/c and heat mode, cooling had a temperature split of 20° and heat had a temperature rise of 35°, air movement system was drawing 1.0 amps, emergency heat was working properly, voltage enhancement systems were within manufacturers specs, compressor drawing 6.5 amps, heatpump is working normally at this time. U.V. bulb needs to be replaced, customer would like a price for it and wanted to see if we could mail it to him.

Near Big Stone Rd, Millington, MD 21651
Craig D.

Craig D.

Replaced 8 outlets and 1 switch. 3 of the outlets were damaged . Need to bring back at a later date a 3 gang white plate with 2 switches and 1 outlet, a 4 way white switch and a 3 way white switch. 6 tandem 20 amp Cutler Hammer breakers.

Near Chesterville Bridge Rd, Millington, MD 21651
Clay K.

Clay K.

Club service two systems, attic system, air filter new, compressor run load amps factory spec 11.7, actual 3.7, outdoor fan full load amps factory spec. 74, actual .5, voltage enhancement system factory spec 35/5, actual 34/4.3, component is rusted but within factory specifications. Basement system, test ran in cooling and found to be low on coolant due to small leaks on the indoor heat exchange system, do not recommend any repairs due to the age of the system.

Near Fords Landing Ln, Millington, MD 21651
Clay K.

Clay K.

No A/C, outdoor air movement system not running, checked and found that the voltage enhancement system is well below the factory spec of 35/5, actual 31.2/5, actual 31.2/.7, do not recommend any other repairs due to the age of the system, A/C system is 20 years old, and the furnace is 4 years old. Installed replacement components and test ran the system, suction 70, liquid 190, delta t 18 degrees, operation within factory specifications at this time.

Near Dogwood Ct, Millington, MD 21651
Tammy A.

Tammy A.

customer signed up for gold club monthly with amanda

Near Dogwood Ct, Millington, MD 21651
Clay K.

Clay K.

Club service A/C, checked system operation, air filter is clean, 21 degrees delta t, compressor run load amps factory spec 10.9, actual 3.9, outdoor fan full load amps factory spec .95, actual .8, voltage enhancement system factory spec 35/5, actual 34.3/5.1, system operation within factory specifications at this time.

Near Spring Rd, Millington, MD 21651
Paul N.

Paul N.

Found problem with voltage conversion system. Also found indoor heat transfer media dirty; voltage enhancer for air circulation system failing and motor bearings are leaking oil; condensate removal pump bad; mismatched A/C equipment, 3-1/2 ton indoor and 4 ton outdoor. Performed basic voltage conversion system repair. Cleaned indoor heat transfer media. Exhaust removal system is noisy and has vibration. Cleaned and tested flame safety system. Adjusted pressure in fuel delivery system. System is working at this time. Recommend replacement of system due to age, condition, cost of future repairs, and improper sizing of A/C equipment.

Near Jim Jungle Rd, Millington, MD 21651
Craig D.

Craig D.

club service oil. Air filter looks clean. Changed nozzle and changed oil filter. cleaned cad cell, cleaned oil gun, cleaned electrodes and adjusted them. smoke test came up clear. bled air/oil out of the system. found indoor voltage enhacement system la ying on the bottom of the cabinet, mouted it to prevent short or spark. oil furnace is running properly at this time.

Near Dudley Corner Rd, Millington, MD 21651
Craig D.

Craig D.

Club Service. Successfully ran heat pump through operation. Return temperature 75 degrees, Warm supply temperature 105, Total heat rise 30 degrees. Filter changed provided by customer. Inspected and Tighten all screws, and electrical connections. brushed off control board, cleaned inside and outside cabinet with microfiber towel, and throughout. Inspected blower motor wheel which looks clean, and runs without restriction. Blower motor amps were 5.1. coil looks clean and drain as well, recommened and installed pan treatment to keep it that way. Successfully Test ran outdoor unit defrost cycle. Rla 7.4 Amps, fla 0.6 amps, Outdoor voltage enhancement system read 37.5/5.4 vs factory spec of 35/5., and is within allowable fault. Voltage gateway system is getting 244 volts through it with no voltage drop and shows no pitting on contacts. unit is working properly at this time.

Near Spring Rd, Millington, MD 21651
Clay K.

Clay K.

Unit not running. Checked air handler and found water switch was open. Checked condensate pan and found a crack in the pan to the indoor coil. Caulked for tempory fix. Also checked refrigerant charge and found no problem.

Near Spring Rd, Millington, MD 21651