Installed supply air sensor for zone system, set dip switch on board to enable.

Near Chesapeake Dr, Havre de Grace, MD 21078
tycaputo95@gmail.com

tycaputo95@gmail.com

Silver package 80k btu 3 ton AC 25' lineset Basement job

Near Chesapeake Dr, Havre de Grace, MD 21078
Keith F.

Keith F.

Talk to Clay about the zone system. Make sure it's working properly He mentioned a communication error in the board. Job to be done Thursday 26th

Near Chesapeake Dr, Havre de Grace, MD 21078
Justin O.

Justin O.

High boy oil furnace replacement

Near Chapel Rd, Havre de Grace, MD 21078
Justin O.

Justin O.

Daikin LV series 12k btu mini split

Near Bayview Dr, Havre de Grace, MD 21078
Craig D.

Craig D.

Voteage enhancement system read 5 / 39 RLA 4.28 FLA 0.55 factory RLA 12.8 FLA 0.95 24 deltat

Near Chapel Rd, Havre de Grace, MD 21078
Keith F.

Keith F.

High boy oil furnace 6 inch pipe Basement Existing 54 inches tall AC is only one year old Remove humidifier

Near Chapel Rd, Havre de Grace, MD 21078
Clay K.

Clay K.

Made repairs to return duct after the plumber had repaired the water leak.

Near Iroquois Ct, Havre de Grace, MD 21078
Clay K.

Clay K.

Water leak above ductwork, cut out return cap so that the plumber can make repair, need to return and patch holes after water line repair is complete.

Near Iroquois Ct, Havre de Grace, MD 21078
Greg H.

Greg H.

Warranty parts and labor arrival found leak at suction king valve used treadsealant to repair leak. Charged system. Operation normal at this time#,moon

Near Ontario St, Havre de Grace, MD 21078
Jeffery A.

Jeffery A.

A/C Rejuvenation on 3 mini split units. Checked temperature split across indoor coils, Cleaned filters. Checked wiring for loose connections and drains for proper operation. Checked outdoor unit heat Pressures are normal. Inspected all wiring for looseness and burns. All voyage is correct. Drained units Systems are cooling at this time.

Near Currier St, Havre de Grace, MD 21078
Clay K.

Clay K.

Very small leak at union, installed replacement, test for leaks.

Near Pointe Way, Havre de Grace, MD 21078
Jeffery A.

Jeffery A.

Upon arrival homeowner stated that unit would trip the breaker and noticed before we came out in September. When inspecting unit, homeowner turned on tstat and unit did not engage. Noticed all bolts were missing and when opened cover noticed comp wire cover was in cabinet. Disconnect was also inserted wrong. As soon as disconnect was properly inserted unit tried to turn in and nothing happened. Noticed comp wires were burned and one prong was loose. Went to ohm out comp and prong came out. Quoted homeowner with repair, decided to get a project manager out on 24th of April at 11a to further discuss options (when choosing a option service fee will get credited into the option chose) Unit is not cooling properly at this time

Near Green St, Havre de Grace, MD 21078
Clay K.

Clay K.

Club heating service inspection: Glow bar=.53 amps flame sensor=.2 micro amps, everything is running at factory spec. Changed media filter and checked blower wheel. 1 media filter left, need more for next visit.

Near Ontario St, Havre de Grace, MD 21078
Greg H.

Greg H.

Duct cleaning. Vacumned return and supply trucks, Vacumned all return and supply branches. Took all registers out and wash them with all purpose cleaner and ripnsed. Cleaned blower and poured cleaner down drain to prevent clogs. Fogged system for 10 minutes. Also cleaned dryer vent.

Near Majestic Prince Cir, Havre de Grace, MD 21078
Steven P.

Steven P.

Installing Pennco gas boiler

Near Green St, Havre de Grace, MD 21078
Ashley  J.

Ashley J.

Delta t 50 Filiter is clean has 1 backup Sensor was dirty got cleaned Sensor 9 Base 1.5 Igniter .9 Air circulation 3.3 Air circulation is dirty Voltage enhancement system 5.9 in factory spects New delta t 53 Complete air circulation system restoration platinum

Near Chesapeake Dr, Havre de Grace, MD 21078
Craig D.

Craig D.

Replaced harness for gas valve, started and tested equipment, system is working normaly at this time.

Near Ontario St, Havre de Grace, MD 21078
Clay K.

Clay K.

Air Ranger very dirty installed replacement, indoor fan amps 5.8, delta t 63 degrees factory spec 35 to 65, fan is on high speed, voltage enhancement system factory spec 20, actual 19.8.

Near Ontario St, Havre de Grace, MD 21078
Clay K.

Clay K.

Delta t 25 Return 75 Supply 100 Flame sensor 2ua Base .7amps Glow stick .9amps Indoor blower 4amps Filter size 14 by 24 Filter no filter inside Voltage enhancement system below manufactur spect

Near Green St, Havre de Grace, MD 21078
Paul N.

Paul N.

Replaced compressor. Brazed in new compressor flowed nitrogen, pressureed tested at 350 psig, Vacumned system to 300 microns, weighed in new refrigerat operation normal at this time

Near Chesapeake Dr, Havre de Grace, MD 21078
Craig D.

Craig D.

Basement floor 5 Stairway to basement 1 Upstairs 5 1st floor has 8

Near Bostonian Way, Havre de Grace, MD 21078
Clay K.

Clay K.

Drain down existing power vent water heater, installed new replacement, also installed replacement expansion system checked for water leaks.

Near Vandiver Ct, Havre de Grace, MD 21078
Craig D.

Craig D.

Indoor unit has a supply of 52 and a return of 77 with a 25 delta. Static pressure supply is 0.12 and return is 0.03. Voltage enhancement system read 5 with a factory setting of 5. Coil looks fine on either side and pan is rusty. Blower dirty and spins without restriction and the bearing is tight. Filter looks ok, recommend checking again at end of the month. Outdoor unit voltage enhancement system read 7.5/39.8 with a factory setting of 7.5/40 and is within allowable fault. System tilted on arrival see photos. Recommend rebalancing system to protect lineset and compressor. Checked disconnect for safety and system normal operation at this time. Quoted for duct cleaning and balancing pad

Near Whitney Ct, Havre de Grace, MD 21078
Craig D.

Craig D.

Checked 3 mini split indoor units, 2 wall mounted and 1 floor mounted unit. Checked temperature split across indoor coils, Cleaned filters and evap coils for all 3 units. Checked wiring for loose connections and drains for proper operation. Checked outdoor heat pump, pressures are normal and wiring is in good condition. System is working normally at this time.