Moon Air provides fast, reliable air conditioning, heating, and electrical services to the residents of Forest Hill, MD and the surrounding areas!

We pride ourselves on a high standard of customer service. Read our reviews and find out why your neighbors consider us to be their preferred HVAC company and electrican in Forest Hill, MD.

Local Reviews
for Forest Hill, MD

Moon Air Inc. Rated 5.0 out of 5 stars based on 2 customer reviews


Map of Forest Hill, MD

Excellence in Service




Review of Moon Air Inc.

Craig never fails to provide excellent customer service. I usually stay with him and watch, mostly to learn and he is also very personable and friendly. He doesn't do a rush job, pays attention to every detail, and he noticeably takes pleasure in knowing how satisfied he is with the work he has done. He keeps our HVAC system ticking!


Map of Forest Hill, MD

Customer Satisfaction




Review of Moon Air Inc.

After listening to your ads via radio Ad nauseam for several years I finally decided I would try Moon Air. Boy! I am glad we did! We've had several HVAC services for our Spring/Fall check-ups, and they were average, but Moon Air goes above and beyond anyone. The team you sent were detailed, patient, thorough and explained everything.


Craig D.

Craig D.

Heating Rejuvenation Indoor unit supply 130 with an 85 with a 45 heat rise. Static pressure is fine. Checked secondary heat exchanger and primary, no signs of corrosion. Voltage enhancement system read 7.2 with a factory setting of 7.5. Cleaned and vacuumed blower wheel and compartment. Changed air filter customer supplied. Changed flapper for Lennox Pulse furnace. Vacuumed out combustion area. Checked wiring connections for safety. Carbon monoxide detectors fine. System normal operation at this time.

Near Bowles Terrace, Forest Hill, MD 21050
Craig D.

Craig D.

Cooling Rejuvenation Indoor unit has supply of 45 with a 65 return and 20 delta. Static pressure supply is 0.33 and return is -0.13. Voltage enhancement system read 7.2 with a factory setting of 7.5 and is within allowable fault. Blower a little dirty, recommend cleaning in fall. Cleaned drain line. Board and wiring looks fine. Checked heat exchanger for safety. Outdoor unit voltage enhancement system read 5/35.9 with a factory setting of 5/35 and is within allowable fault. The FLA is 0.53 (f1.1) and RLA 6.6 (f13.5). Cleaned outdoor coil, exterior and interior. Checked disconnect for safety and system normal operation at this time. Return trunk very dirty, both supply and return trunks have patches.

Near Bowles Terrace, Forest Hill, MD 21050
Craig D.

Craig D.

Indoor unit has a supply of 154 with a return of 80 with a 74 heat rise. Static pressure supply is 0.3 and return is -0.17. Voltage enhancement system read 7.2 with a factory setting of 7.5 and is within allowable fault. Blower compartment a little dirty, some of insulation coming apart but for most part holding together. Blower wheel a little dirty, spins without restriction and the bearing is tight. Checked wiring behind thermostat terminal and connections are good. Cleaned out filter of exhaust removal system of bugs. Amps for exhaust removal system read 0.3. Changed filter customer supplied, it was a 4 inch and filter slot can take up to a five inch. Checked heat exchanger looks ok. Ignition ceased when turning off fuel delivery system. Recommended they replaced carbon monoxide detector.

Near Bowles Terrace, Forest Hill, MD 21050
Clay K.

Clay K.

Install follow-up, customer stated noise from unit, cycled several times, could not get system to make a noise besides indoor fan start up, put system into fan on at t-stat.

Near Bower Ln, Forest Hill, MD 21050
Steven P.

Steven P.

Installing new Amana 16 SEER 3.5Ton AC and 80% 80k furnace for the first floor and 80% 60k BTU furnace for the second floor with two honeywell lyric wifi thermostats

Near Bower Ln, Forest Hill, MD 21050
Gerald T.

Gerald T.

First floor system - 17-year-old 80% efficient natural gas furnace and 17-year-old condenser. Cooling - The outside ambient temp was approximately 75 degrees and the indoor dry bulb was 71. The air filter was new and didn't need to be replaced. The cool supply air was 55 degrees and the room temperature return air was 70 degrees for a Delta T of 15. Measured 6.9 Amperes and 120 Volts on the air circulation system, and its voltage enhancer had an inorrect uF charge. It only registered 8 uF and that's below the manufacturer's recommended rating. It should be replaced. Verified the circuit board and wiring were in good condition with nothing frayed. Cleaned the air circulation compartment and blower. Purged the condensation pipe with CO2 and added some descaler to its U trap to prevent clogs. The refrigerant pumping system's run amps were 15.5 (too high (RLA is 17)), the start amps were 5.2, and the air exhaust system's amps were .6 (FLA is 1.4). Cleaned the electrical compartment and c

Near Bower Ln, Forest Hill, MD 21050
Gerald T.

Gerald T.

First floor system - 17-year-old 80% efficient natural gas furnace and 17-year-old condenser. Cooling - The outside ambient temp was approximately 75 degrees and the indoor dry bulb was 71. The air filter was new and didn't need to be replaced. The cool supply air was 55 degrees and the room temperature return air was 70 degrees for a Delta T of 15. Measured 6.9 Amperes and 120 Volts on the air circulation system, and its voltage enhancer had an inorrect uF charge. It only registered 8 uF and that's below the manufacturer's recommended rating. It should be replaced. Verified the circuit board and wiring were in good condition with nothing frayed. Cleaned the air circulation compartment and blower. Purged the condensation pipe with CO2 and added some descaler to its U trap to prevent clogs. The refrigerant pumping system's run amps were 15.5 (too high (RLA is 17)), the start amps were 5.2, and the air exhaust system's amps were .6 (FLA is 1.4). Cleaned the electrical compartment and c

Near Bower Ln, Forest Hill, MD 21050
Steve M.

Steve M.

Free estimate on rooftop air conditioning replacement

Near Robin Cir, Forest Hill, MD 21050
Steve M.

Steve M.

Replacing a Trane heat pump with a Rheem gas furnace air conditioner hybrid system

Near Water Tower Way, Forest Hill, MD 21050