Goodman 2.5 ton AC and Coil with new thermostat

Near W Court Ave, Claymont, DE 19703
Craig D.

Craig D.

Clean and checked a/c system, 21 degree temperature split across indoor coil, air filter had been changed recently but recommend replacing soon, blower wheel was clean and condensate removal system working properly. All voltages, amperages and systems were all within manufacturers specs for indoor and outdoor units, system is working normally at this time.

Near Honeywell Dr, Claymont, DE 19703
Craig D.

Craig D.

14 SEER 2 Ton AC and 80% 60k furnace

Near Wiltshire Rd, Claymont, DE 19703
Clay K.

Clay K.

Club service gas with A/C, outdoor system was very dirty, chemically cleaned and test ran, 18 degrees delta t, compressor run load amps factory spec 15.4, 7.4, outdoor fan full load amps factory spec. 95, actual. 9, voltage enhancement system factory spec 45/5, actual 44.7/4.8, within factory specifications. Test ran furnace and changed customer supplied filter, inducer fan amps. 4, glow bar .3, flame current 2.2 uamps, indoor fan 2.6, operation normal at this time.

Near Miles Rd, Claymont, DE 19703
Steven P.

Steven P.

Installing 14 SEER 2 Ton AC and 80% 60k Furnace with new line set and thermostat. 10 year parts, 10 year compressor, lifetime heat exchanger, and 1 year labor warranty

Near Wiltshire Rd, Claymont, DE 19703
Steven P.

Steven P.

Installing Goodman 14 SEER 2.5 Ton AC and coil with new line set and condensate pump to re-route the drain out by the condenser. We will also perform a “tune-up” and check over of our furnace that we installed. Install scheduled for 9/28 when Justin is back in town

Near W Court Ave, Claymont, DE 19703
Craig D.

Craig D.

Ower stated water was entering inside panel from main cable. Removed meter cover and sealed load side cable with silicone caulk. Removed pvc lb cover and took picture of sediment lining in lb bottom. Seal back opening with duct seal to prevent any water from entering home .

Near Philadelphia Pike, Claymont, DE 19703
tkilby1976@icloud.com

tkilby1976@icloud.com

Performed electrical inspection on basement outlets and switches. There are a few minor fixes to be done. Installed GFCI outlet BEHIND bar and tightened all outlets and put plates where necessary.

Near Nikhil Ct, Claymont, DE 19703
Clay K.

Clay K.

Club service A/C, changed customer supplied air filters, 2 - 16x25x1, test ran system in cooling, 18 degree delta t, compressor run load amps factory spec 17.9, actual 8.6, outdoor fan full load amps factory spec 1.5, actual 2.2 voltage enhancement system factory spec 45/5, actual 44.5/4.9, operation within factory specifications at this time.

Near Drexel Rd, Claymont, DE 19703
Craig D.

Craig D.

In heating the supply is 128 with a 72 return with a 56 delta. Blower wheel was a little dirty so cleaned it, blower compartment looks good. Blower wheel spins without restriction and the bearing is tight. There is no C0 detector near furnace, strongly recommend that customer has one installed. Checked ductwork near filters and saw dirt and dust, also used camera to check ductwork even further and saw more dust/dirt build up and recommend a duct cleaning. Board looks good with no burn marks on it and connections are tight. Cleaned condensate line with brush and checked condensate lines from secondary heat exchanger and exhaust removal system, both are clear. Exhaust removal system clicks while spinning and had an amp reading of 3.13 with a factory setting of 2.8 and is above allowable fault. Limit switch had an amp reading of 0.4. Cleaned burners and flame safety, both had no distortions. Flame ignitor looks good too. Gas shut off working properly, ignition occurred no problems with th

Near Drexel Rd, Claymont, DE 19703
Craig D.

Craig D.

Mini split system. Indoor systems. Heat and fan modes working properly on all systems. All coil systems clean. Cleaned all air filtration systems. Outdoor systems. Coil systems clean and working properly. All systems working as they should be. Nat gas furnace. Replaced air filtration system per customer. Air movement and circulation system clean. Cleaned sensor system. Cleaned flame distribution system. Both air movement and air exhaust systems have correct uf charges. No cracks or hot spots on ignition system. Flame rectification proven. Fuel delivery system set to proper pressure. All systems running at proper voltages and amperes. All safety systems working properly. Temperature rise within factory specifications. No other concerns at this time.

Near Philadelphia Pike, Claymont, DE 19703
Craig D.

Craig D.

In cooling the indoor unit has a supply of 44 with a 64 return and 20 delta. In heat the supply is 139 with a 84 return and a 55 delta. Cleaned air ranger grate, replaced media with new one customer supplied they have no extra. Tons of dirt build up on air ranger, recommend duct cleaning. Cleaned flame sensor, checked ignitor and both look good. Cleaned burners and gas valve, there was no obstruction between fins and nothing was distorted. Voltage absorption system read 4.9 with a factory setting of 5 and is within allowable fault in the Inducer motor. The Inducer motor amps were 0.2 and the blower motor amps were 3.4. Blower looks clean, compartment was wiped up, clean exterior of furnace. UV light on third year, recommend replacement to retain effectiveness.

Near Miles Rd, Claymont, DE 19703
Clay K.

Clay K.

Returned and installed replacement power system for Air Ranger Air Filteration system, checked operation, working normal at this time.

Near Providence Ave, Claymont, DE 19703
Craig D.

Craig D.

Upon arrival no cooling, turned thermostat on and furnace came on no problem. Went outside and could hear compressor trying to turn on, checked voltage absorption system and it read 4/0 with a factory setting of 5/45 and had failed. Checked contacts on gateway and saw no visible damage and also checked disconnect and there are no burnt wires. After repair system has a supply of 60 and a return of 75 with a 15 delta. System normal operation at this time.

Near Drexel Rd, Claymont, DE 19703
Gerald T.

Gerald T.

Two-year-old Amana 80% efficient natural gas furnace, and 17-year-old Amana condenser. The outdoor ambient temp was approximately 85 degrees, the indoor dry bulb was 77, the indoor wet bulb was 66, and the relative humidity was 60%. Removed the extremely dirty air filter and told the customer to buy more and replace them more often. The current one was from our visit on 12/26/18. The cool supply air was 58 and the room temperature return air was 74 for a Delta T of 16. Based on these readings the cool supply temp is excellent. Measured 7.75 Amperes on the air circulation system, and its voltage enhancer had a correct uF charge. Cleaned the indoor coil, verified the circuit board and wiring were in good condition, and purged the water removal system's discharge tube with CO2 to prevent clogs (also confirmed it was working). Confirmed the outdoor coil was clean, cleaned the electrical compartment, and confirmed the blades, disconnect, wiring, and voltage distributor were in good conditio

Near Honeywell Dr, Claymont, DE 19703
Gerald T.

Gerald T.

Two-year-old Amana 80% efficient natural gas furnace, and 17-year-old Amana condenser. The outdoor ambient temp was approximately 85 degrees, the indoor dry bulb was 77, the indoor wet bulb was 66, and the relative humidity was 60%. Removed the extremely dirty air filter and told the customer to buy more and replace them more often. The current one was from our visit on 12/26/18. The cool supply air was 58 and the room temperature return air was 74 for a Delta T of 16. Based on these readings the cool supply temp is excellent. Measured 7.75 Amperes on the air circulation system, and its voltage enhancer had a correct uF charge. Cleaned the indoor coil, verified the circuit board and wiring were in good condition, and purged the water removal system's discharge tube with CO2 to prevent clogs (also confirmed it was working). Confirmed the outdoor coil was clean, cleaned the electrical compartment, and confirmed the blades, disconnect, wiring, and voltage distributor were in good conditio

Near Honeywell Dr, Claymont, DE 19703
Craig D.

Craig D.

Indoor unit has a supply of 50 and a return of 65 with a 15 delta. Air filter dirty, recommend changing or changing soon. The voltage absorption system read 4 with a factory setting of 5 and is below allowable fault. Blower wheel looks good, blower compartment was a little dirty but wiped clean. Blower wheel spins without restriction and the bearing is tight. Heat exchangers look good. Coil and pan look good, cleared condensate line with c02 and taped insulation back against inner cabinet. The outdoor unit voltage absorption system read 5/45 with a factory setting of 5/45. The FLA is 0.7 with a factory setting of 1.1 and the RLA is 6.4 with a factory setting of 16.7. The disconnect was tightened.

Near Osage Rd, Claymont, DE 19703
Clay K.

Clay K.

Checked filtration system, Air Ranger, have 24 vac going to the power pack but the pack is not on, removed cover and found that the pack has failed and needs to be replaced.

Near Providence Ave, Claymont, DE 19703
Craig D.

Craig D.

Indoor unit has a supply of 47 and a return of 62 with a 15 delta. Air ranger working fine, cleaned grill filter media fine. Coil and pan look good, cleaned condensate line with c02. Ductwork looks ok with no visible compromises. Heat exchanger looks good. Blower compartment looks good as does blower wheel. Blower wheel spins without restriction and the bearing is tight. Outdoor unit voltage absorption system read 4.9 / 44.7 with a factory setting of 5/45 and is within allowable fault. Dug out winter debris.

Near Miles Rd, Claymont, DE 19703
Gerald T.

Gerald T.

10-year-old Trane natural gas furnace and 17-year-old Trane condenser. The outdoor ambient temp was approximately 76 degrees, the indoor dry bulb was 74, the indoor wet bulb was 61, and the relative humidity was 50%. Replaced the dirty air filter with one provided by the customer. The cool supply air was 55 degrees and the room temperature return air was 70 for a Delta T of 15. Based on these readings the supply air temp is excellent. Measured 4.55 Amperes on the air circulation system and verified the circuit board and wiring were in good condition. Cleaned the EZ Trap safety sensor and added some descaler to it to prevent clogs. The refrigerant pumping system's run amps were 11 (RLA is 13), the start amps were 6.1, and the air exhaust system's amps were .6 (FLA is 1.3). A resistance check on these systems' windings proved they are not failing but the run amps were a little too close to the RLA. Confirmed the blades, disconnect, wiring, and voltage distributor were in good condition.

Near Honeywell Dr, Claymont, DE 19703
Gerald T.

Gerald T.

10-year-old Trane natural gas furnace and 17-year-old Trane condenser. The outdoor ambient temp was approximately 76 degrees, the indoor dry bulb was 74, the indoor wet bulb was 61, and the relative humidity was 50%. Replaced the dirty air filter with one provided by the customer. The cool supply air was 55 degrees and the room temperature return air was 70 for a Delta T of 15. Based on these readings the supply air temp is excellent. Measured 4.55 Amperes on the air circulation system and verified the circuit board and wiring were in good condition. Cleaned the EZ Trap safety sensor and added some descaler to it to prevent clogs. The refrigerant pumping system's run amps were 11 (RLA is 13), the start amps were 6.1, and the air exhaust system's amps were .6 (FLA is 1.3). A resistance check on these systems' windings proved they are not failing but the run amps were a little too close to the RLA. Confirmed the blades, disconnect, wiring, and voltage distributor were in good condition.

Near Honeywell Dr, Claymont, DE 19703
Clay K.

Clay K.

Indoor Air Ranger metal cage was cleaned, customer said they replaced the air filter. Let customer know that I didnt see any extra air filters. Return temp was 67 and the supply temp was 47. The capacitor in the heat pump was reading 4.9 with a factory spec of 5. The blower motor amps were 6.7. Outdoor condensor capacitor was reading 4.9/29.7. Was functioning below factory spec so was replaced. FLA was 0.6 with a factory setting of 1.1. The RLA was 4.4 with a factory setting of 12.2. Both working fine.

Near Providence Ave, Claymont, DE 19703
Gerald T.

Gerald T.

I just made sure another Trane air conditioner is ready for the rest of the summer and it's a neighbor of an existing customer.

Near Honeywell Dr, Claymont, DE 19703
Gerald T.

Gerald T.

I just made sure another Trane air conditioner is ready for the rest of the summer and it's a neighbor of an existing customer.

Near Honeywell Dr, Claymont, DE 19703
Gerald T.

Gerald T.

Making sure another customer with an Amana air conditioner is set for the rest of the summer.

Near Glenrock Dr, Claymont, DE 19703