Filters were very dirty took them out recommend changing filters soonWiped down furnace and door p Checked eletrical conections. Blower voltage enhancement system read 7.3 vs 7.5. Pulled blower wheel it is clean. Checked heat exchanger found no areas of concern burner and thermocouple look ok. Checked for gas leaks no leaks found operation normal at this time

Near Coon Box Rd, Centreville, MD 21617
Greg H.

Greg H.

Heat rise with factory spec blower and evaporator are clean. Burners and flame sensing system are clean. Checked eletrical conections. Heat exchanger has no areas of concern. Voltage enhancement system for blower read within factory spec installed surge protector for ac unitoperation normal at this time

Near Willow Branch Rd, Centreville, MD 21617
Keith F.

Keith F.

Will give her estimate later today and discuss moving forward

Near Wharf Ln, Centreville, MD 21617
Craig D.

Craig D.

Cooling Rejuvenation Outdoor unit voltage enhancement system read 5/43.8 with a factory setting of 5/45. FLA 0.6 and RLA 6.3. Cleaned coil and exterior, interior drain clear. Checked disconnect and wiring connections for safety. Indoor unit supply 64 with an 84 return and 20 delta. Static pressure is fine. Coil and pan is fine. Blower spins without restriction. Board and connections are fine. Cleaned drain line with cleaner and brush. All three air filters should be replaced soon. System normal operation at this time.

Near Burrisville Rd, Centreville, MD 21617
Paul N.

Paul N.

Conditioned room above garage but temperature not desirable. Going over notes with Steve to come up with a plan.

Near Solitude Ln, Centreville, MD 21617
Craig D.

Craig D.

Cooling Rejuvenation Outdoor unit voltage enhancement system read 5/38.5 with a factory setting of 5/40. FLA 0.6 and RLA 5.1. Installed performance kit. Cleaned coil and exterior, interior clear. Checked disconnect for safety. Tested operation with performance kit. Indoor unit supply 53 with a 71 return and 18 delta. Static pressure is fine. Changed air filter customer supplied. Blower spins without restriction. Board and connections fine. Removed 2 dead mice from return drop. Cleaned and disinfected area. System normal operation at this time.

Near Church Hill Rd, Centreville, MD 21617
Jeffery A.

Jeffery A.

A/C Rejuvenation Preformed Inspected indoor unit, Electrical components and safety controls are working properly, return grill and plenum are clean, filter is clean, evaporator coil is clean, blower is clean , supply and return is clean. Inspected wiring for any cracks, looseness or burns. Inspecting electrical components for proper reading. DT was witching recommended range. Ducts are properly installed and secure Inspected outdoor unit. Electrical Components are working properly, refrigerant pressures good. Cleaned cabinet and washed out coil. Inspected electrical components for proper readings. Refrigerant levels are good. SH/SC was within range. Fan was secured. Tested All components, all are within recommended range Unit is properly cooling at this point in time

Near Willow Branch Rd, Centreville, MD 21617
Jeffery A.

Jeffery A.

Checked refrigerant levels according to Pressure Temperature chart as well as SH/SC chart. Unit was requiring 13 Degrees of SC , unit is at 15 Degrees. Unit is running properly within recommended range by manufacture. Unit is properly cooling at this time

Near Solitude Ln, Centreville, MD 21617
Paul N.

Paul N.

4 ton heat pump 16 seer two stage Crael space 32x23.5 Air handler 54x22 Supply duct 15x10 Return is 8, 8" flex coming off plenum

Near Solitude Ln, Centreville, MD 21617
Ashley  J.

Ashley J.

Delta t 47 Filter is dirty Sensor was cleaned Sensor 6 amps Base 1.2 amps Igniter .4 amps Air circulation 2.8 Air circulation was cleaned Everything is in factory spects at this time

Near Church Hill Rd, Centreville, MD 21617
Greg H.

Greg H.

Furnace rejuv tenp rise 50 degrees. draft motor amps 2.8. Blower motor amps 5.8. Blower voltage enhancement system read below factory spec of 11.7 vs 12.5 replaced new voltage enhancement system read 12.5. Cleaned flame sensor, Checked igniter. Checked burners and they are clean of debris. Checked blower wheel. Did wd40 wipedown operation normal at this time

Near Willow Branch Rd, Centreville, MD 21617
Craig D.

Craig D.

Indoor unit has a supply of 49 and a return of 71 and a 22 delta. Static pressure supply is 0.27 and return is -0.58. Blower and compartment looked fine, blower wheel spins without restriction and the bearing is tight. Filter looks fine, recommend checking again at end of August. Cleaned drain line with brush, coil sealed behind sheet metal. Outdoor unit voltage enhancement system read 5/38.9 with a factory setting of 5/40 and is within allowable fault. The suction line was cold and liquid line warm. Coil dirty so cleaned, cleaned interior and exterior. Checked disconnect for safety and system normal operation at this time. Recommending performance kit upgrade for system to help keep compressor healthy.

Near Church Hill Rd, Centreville, MD 21617
Craig D.

Craig D.

Indoor unit has a supply of 48 and a 69 return of with a 21 delta. Both sides of coil look good and pan is clean. Condensate line clear and pumpis running. Blower wheel looks fine and spins without restriction and the bearing is tight. Voltage enhancement system read 12.2 with a factory setting of 12.5 and is within allowable fault. Checked air filter and should be changed next month at latest. Outdoor unit voltage enhancement system read 5/40 with a factory setting of 5/40. The FLA is 0.6 and the RLA is 5.5. Inside drain holes clear, washer coil and cleaned exterior. Checked disconnect for safety and system normal operation at this time.

Near Willow Branch Rd, Centreville, MD 21617
Clay K.

Clay K.

No hear new install, checked system, outdoor unit in lock-out due to pressure trips, checked indoor air filters, 3 of the four were very dirty, removed and customer will replace, did not have any spares, test ran unit at 74 deg indoor, 54 deg outdoor, factory spec 111 suctiob 370 discharge, actual 115/360 operation normal at this time.

Near Burrisville Rd, Centreville, MD 21617
Craig D.

Craig D.

Club Service. Successfully ran seven year old LP gas warm air furnace through all stages of operation. Home owner uses baseboard heat ost of the time so the furnace does not get used much at all. OReturn temperature 70 degrees, warm supply temperature 123 degrees, total heat rise 35 degrees. filter recently changed by customer. at room temp the igniter read 55 ohms and is within allowable fault. stack temp 108, co2 8.6, ef 91% Draft motor amps were 2.8. gas pressure LO 5.7 w.c, HI 9.7 w.c Within a timely manner the gas valve click and ignited into a solid blue flame with slight orangeing but no yellow tips or roll backs . Cleaned flame sensor, all burners look clean, brushed off control board, cleaned inside and outside cabinet with microfiber towel, Inspected blower motor wheel which looks clean and runs without restriction. Blower motor amps werewithin normal factory spec, which means it is also within allowable fault. T ightened all screws, and electrical connections. Furnace

Near Willow Branch Rd, Centreville, MD 21617
Craig D.

Craig D.

Rejuvenation lp furnace. Recommend air filtration system to be replaced. Air movement and circulation system clean. Ignition system has no burn spots. Cleaned sensor system. Flame distribution system clean. Flame rectification proven. All systems running at proper voltage and amperes. Fuel distribution system set properly for both low and high stages. All safety systems working properly. Heat rise within factory specs. No other concerns with heating system at this time.

Near Church Hill Rd, Centreville, MD 21617
Craig D.

Craig D.

Indoor unit has a supply of 110 and a return of 86 with a 34 delta. Voltage absorption system read 7.3 with a factory setting of 7.5 and is within allowable fault. Pilot light had a healthy flame, when unit turned on could clearly see blue flame. Blower wheel was cleaned and spins without restriction and the bearing is tight. Filter looks good, recommend checking in 60 days.

Near Coon Box Rd, Centreville, MD 21617
Craig D.

Craig D.

16 SEER Heat Pump and ECM Air Handler

Near Burrisville Rd, Centreville, MD 21617
Steven P.

Steven P.

Installing Amana 16 SEER 3.5 Ton Heat Pump and ECM air handler with 10 year parts, 10 year labor and lifetime unit replacement warranty

Near Burrisville Rd, Centreville, MD 21617
Gerald T.

Gerald T.

Seven-year-old propane furnace and condenser. The outdoor ambient temp was approximately 67 degrees and the indoor dry bulb was 72. Checked the air filter and it didn't need to be replaced. The cool supply air was 46 degrees and the room temperature return air was 67 degrees for a Delta T of 21. Measured 5.5 Amperes and 120 Volts on the air circulation system and its voltage enhancer had a correct uF charge. Verified the circuit board and wiring were in good condition, the indoor coil wasn't dirty, and no leak was detected. Purged the condensation pipe and the condensation pump's discharge tube with CO2 (and added some descaler) to prevent clogs. The refrigerant pumping system's run amps were 5.6 (RLA is 15), the start amps were 4.9, and the air exhaust system's amps were .65 (FLA is 1.1). Cleaned the electrical compartment, and verified the blades, disconnect, wiring, and voltage distributor were in good condition. The latter had a normal 240 Volts across it. The outside voltage enhan

Near Willow Branch Rd, Centreville, MD 21617
Gerald T.

Gerald T.

Seven-year-old propane furnace and condenser. The outdoor ambient temp was approximately 67 degrees and the indoor dry bulb was 72. Checked the air filter and it didn't need to be replaced. The cool supply air was 46 degrees and the room temperature return air was 67 degrees for a Delta T of 21. Measured 5.5 Amperes and 120 Volts on the air circulation system and its voltage enhancer had a correct uF charge. Verified the circuit board and wiring were in good condition, the indoor coil wasn't dirty, and no leak was detected. Purged the condensation pipe and the condensation pump's discharge tube with CO2 (and added some descaler) to prevent clogs. The refrigerant pumping system's run amps were 5.6 (RLA is 15), the start amps were 4.9, and the air exhaust system's amps were .65 (FLA is 1.1). Cleaned the electrical compartment, and verified the blades, disconnect, wiring, and voltage distributor were in good condition. The latter had a normal 240 Volts across it. The outside voltage enhan

Near Willow Branch Rd, Centreville, MD 21617
Gerald T.

Gerald T.

Making sure another Delmarva customer is prepared to get cool air out of their Amana AC unit during the hot season.

Near Church Hill Rd, Centreville, MD 21617
Gerald T.

Gerald T.

Making sure another Delmarva customer is prepared to get cool air out of their Amana AC unit during the hot season.

Near Church Hill Rd, Centreville, MD 21617
Gerald T.

Gerald T.

Ensuring another Trane heat pump is generating enough cool air for the upcoming hot season.

Near Burrisville Rd, Centreville, MD 21617
Gerald T.

Gerald T.

Ensuring another Trane heat pump is generating enough cool air for the upcoming hot season.

Near Burrisville Rd, Centreville, MD 21617