Paul N.

Paul N.

Utica 140 MBH oil boiler

Near 1st Ave, Betterton, MD 21610
Paul N.

Paul N.

Paul stopped and got a material list for install on 9/22

Near 1st Ave, Betterton, MD 21610
Steven P.

Steven P.

Installing Utica 140 MBH oil boiler

Near 1st Ave, Betterton, MD 21610
Clay K.

Clay K.

No heat Navien tankless system, checked and found to be in lock out, E12, loss of flame, reset system and started to operate with no problems, 10.9"wc inlet, checked customers propane tank and it is at 80%, totally full, most likely ran out of fuel, tanks can only be filled to 80% to allow for expansion (see photos).

Near 1st Ave, Betterton, MD 21610
Steven P.

Steven P.

Furnace dimensions: 19.5x54 Conversion to propane- 96% 2-stage 80.3 with chimney liner

Near 6th Ave, Betterton, MD 21610
Clay K.

Clay K.

No heat, system off on E12 code, loss of flame, restarted and test ran, cleared condensate trap system with CO2, working g normal at this time, some drips from collection tray but they stopped.

Near 1st Ave, Betterton, MD 21610
Ashley  J.

Ashley J.

Changed the oil filter Checked Sensor Changed the nozzle and cleaned the gun Wiped down system Everything is in factory spects at this time

Near 6th Ave, Betterton, MD 21610
Craig D.

Craig D.

Heating Rejuvenation Indoor head living room to left of door has supply of 112 and an 84 return with a 28 delta. Cleaned filters, washed coil with water and cleaned exterior. Indoor head dining room has a supply of 109 and an 83 return with a 26 delta. Cleaned filters, washed coil with water and cleaned exterior. Indoor head 2nd floor bedroom nearest stairs has a supply of 113 and a return of 83 with a 30 delta. Cleaned filters, washed coil with water and cleaned exterior. Indoor head master bedroom has a supply of 116 and a return of 84. Cleaned coil with water, filters and exterior. Updated 3 remotes with correct time/day, system normal operation at this time.

Near 1st Ave, Betterton, MD 21610
Steven P.

Steven P.

Installing new oil furnace and AC in basement with filter rack and new chimney cap. Total project $8,623 - $109 service call = $8,514. Need to update estimate to reflect $8,514 total project.

Near Idlewhile Ave, Betterton, MD 21610
Craig D.

Craig D.

Found compressor has failed internally, recommend replacing system due to age and overall condition of the equipment. Having project manager give them a quote on replacement. Also chimney cap has fallen off, found it by condenser, looks like it has been off for quite some time.

Near Idlewhile Ave, Betterton, MD 21610
Clay K.

Clay K.

Condensate leak from the bedroom system, drain line clogged with dirt, cleared with CO2, test with water.

Near 1st Ave, Betterton, MD 21610
Craig D.

Craig D.

Indoor unit has a supply of 51 and a return of 70 with a 19 delta. Voltage enhancement system read 9.6 with a factory setting of 10 and is within allowable fault. Blower wheel looks good and spins without restriction and the bearing is tight. Coil and pan are clean, cleaned condensate line with cleaner. Checked air filter, looks ok and recommend customer checks again at end of May. Outdoor unit voltage enhancement system read 4.9/34.1 with a factory setting of 5/35 and is within allowable fault. Cleaner outdoor coil and cleaned out debris in condensor. Checked disconnect, normal operation at this time.

Near 6th Ave, Betterton, MD 21610
Clay K.

Clay K.

Checked tankless system, no fault codes on display, reset boiler and system started, house temp now at 55 deg, was 49 deg. could not get system not to work.

Near 1st Ave, Betterton, MD 21610
Clay K.

Clay K.

Returned and made repaires to Head unit on left, replaced tha main air movement system, checked for noise, operation normal at this time.

Near 1st Ave, Betterton, MD 21610
Greg H.

Greg H.

Oil boiler club service. Changed nozzle 1.00 by 80 w. Changed oil filter, filter screen looks clear, cleaned cad cell, cleaned gun assembly, cleaned electrodes adjusted electrodes, did smoke test and came up clear. Cleaned heat exchanger, checked pump pressure, cleared air out of the system pressure and temperature both are within factory spec, tested pressure relief valve, all electrical connections look good boiler is running properly at this time.#-moon.

Near 6th Ave, Betterton, MD 21610
Clay K.

Clay K.

Club srevice Mini-Split system, test ran nall systems in heat mode, checked all filters, 1st floor unit on the left the air movement wheel is out of balance and needs to be replaced, other than that, units working within factory spec.

Near 1st Ave, Betterton, MD 21610
Gerald T.

Gerald T.

18-year-old Armstrong oil furnace, 10-year-old Goodman condenser, three-year-old Carrier indoor coil. The outside ambient temp was approximately 65 degrees and the indoor dry bulb was approximately 68. The cool supply air was 47 degrees and the room temperature return air was 65 for a Delta T of 18. Measured 4.75 Amperes on the air circulation system and its voltage enhancer had a correct uF charge. The indoor coil was clean and I purged the water removal system's discharge tube with CO2 and added some descaler to it to prevent clogs. The refrigerant pumping system's run amps were 4.85 (RLA is 14), the start amps were 4.4, and the air exhaust system's amps were .6 (FLA is 1.1). Cleaned the electrical compartment, and confirmed the outdoor coil was clean and the blades, disconnect, wiring, and voltage distributor were in good condition. The latter had a normal 245 Volts in and out of it. The outdoor voltage enhancer had a correct uF charge.

Near 6th Ave, Betterton, MD 21610
Gerald T.

Gerald T.

18-year-old Armstrong oil furnace, 10-year-old Goodman condenser, three-year-old Carrier indoor coil. The outside ambient temp was approximately 65 degrees and the indoor dry bulb was approximately 68. The cool supply air was 47 degrees and the room temperature return air was 65 for a Delta T of 18. Measured 4.75 Amperes on the air circulation system and its voltage enhancer had a correct uF charge. The indoor coil was clean and I purged the water removal system's discharge tube with CO2 and added some descaler to it to prevent clogs. The refrigerant pumping system's run amps were 4.85 (RLA is 14), the start amps were 4.4, and the air exhaust system's amps were .6 (FLA is 1.1). Cleaned the electrical compartment, and confirmed the outdoor coil was clean and the blades, disconnect, wiring, and voltage distributor were in good condition. The latter had a normal 245 Volts in and out of it. The outdoor voltage enhancer had a correct uF charge.

Near 6th Ave, Betterton, MD 21610
Gerald T.

Gerald T.

14-year-old oil-fired boiler. Checked the outside oil tank and it was in good condition (it was full). Replaced the oil line filter and gaskets and cleaned the oil canister. Replaced the burner tube nozzle and checked and cleaned the electrodes, cad cell, igniter springs, and turbulator. Camera inspected the heat exchanger and checked the pump pressure. Didn't detect any problems with soot in the chimney pipe or holes in it. Smoke tested it and made a slight change to the air shutter for a cleaner burn. The water temp and pressure were normal.

Near 6th Ave, Betterton, MD 21610
Gerald T.

Gerald T.

14-year-old oil-fired boiler. Checked the outside oil tank and it was in good condition (it was full). Replaced the oil line filter and gaskets and cleaned the oil canister. Replaced the burner tube nozzle and checked and cleaned the electrodes, cad cell, igniter springs, and turbulator. Camera inspected the heat exchanger and checked the pump pressure. Didn't detect any problems with soot in the chimney pipe or holes in it. Smoke tested it and made a slight change to the air shutter for a cleaner burn. The water temp and pressure were normal.

Near 6th Ave, Betterton, MD 21610
Sean D.

Sean D.

replace defective evap coil

Near 6th Ave, Betterton, MD 21610
Chris S.

Chris S.

• Working on a international comfort products air conditioner repair. Installed new direst drive blower motor for the condenser fan along with a new capacitor for the motor started and tested air conditioner no other issues noted at this time.

Near Ericsson Ave, Betterton, MD 21610
Chris S.

Chris S.

Working on a international comfort products air conditioner repair. Installed new direst drive blower motor for the condenser fan along with a new capacitor for the motor started and tested air conditioner no other issues noted at this time.

Near Betterton, MD
Chris S.

Chris S.

Compressor locked out and system will not run on a 11-15 Year Old RUUD with R-22 (HVAC IAQ) Air duct cleaning service and an air purifier would greatly enhance this home's air quality.

Near Idlewhile Ave, Betterton, MD 21610