Craig D.

Craig D.

In heating the supply is 125 with a 73 return and a 52 delta. Exhaust removal amps are 1.8, high limit amps 0.5, pressure switch amps 0.4. Voltage enhancement system read 7.5 with a factory setting of 10 and is below allowable fault with an amp reading of 6.3. Blower wheel was dirty and cleaned, compartment looks good. Blower wheel spins without restriction and the bearing is tight. Air filter is a 16x25x5 and is dirty, recommend replacing asap. Ignitor ignited gas on first try and has some markings on it. Ignition occurred with no problems with the flame being blue with hints of orange and no flames rolling back. System normal operation at this time.

Near Raking Leaf Dr, Abingdon, MD 21009
Craig D.

Craig D.

Indoor unit attic has a supply of 135 with a return of 73 with a 62 delta. Voltage enhancement system read 19.8 with a factory setting of 20 on the blower and is within allowable fault. Blower wheel and compartment look good with the blower wheel spinning without restriction and the bearing is tight. Board has no burn marks on it and connections are tight. Cleaned air ranger grate and replaced media customer supplied, recommend customer checks sooner and has ducts cleaned to help maintain air cleaners efficiency. Cleaned burners and flame safety system, both look good. Ignitor looks good too. Ignition occurred with no problems, flame was blue with no flames rolling back. Indoor unit basement has a supply of 125 and return of 74 with a 51 delta in heating. Blower wheel and compartment were dirty and cleaned. Blower wheel spins without restriction and the bearing is tight. Board looks good and the connections are tight. Voltage enhancement system on exhaust removal system read 5 with a

Near Airdrie Ave, Abingdon, MD 21009
Gerald T.

Gerald T.

Three-year-old Lennox system. Upon arrival the air circulation system was working, but the air exhaust and refrigerant pumping systems would not start. The Delta T between supply air and return air was zero. The liquid and vapor pressures were negligible and the fault code in the outdoor circuit board indicated the system has tripped out on low pressure. The refrigerant leak detector test proved positive on many areas of the indoor coil. The system is low on refrigerant due to a leaking indoor coil.

Near Parallel Path, Abingdon, MD 21009
Gerald T.

Gerald T.

Three-year-old Lennox system. Upon arrival the air circulation system was working, but the air exhaust and refrigerant pumping systems would not start. The Delta T between supply air and return air was zero. The liquid and vapor pressures were negligible and the fault code in the outdoor circuit board indicated the system has tripped out on low pressure. The refrigerant leak detector test proved positive on many areas of the indoor coil. The system is low on refrigerant due to a leaking indoor coil.

Near Parallel Path, Abingdon, MD 21009
Craig D.

Craig D.

2nd floor unit not cooling. Still under warranty. Found indoor fan running but outdoor unit not running. Found trap safety switch stuck. Cleaned switch and verified proper operation of it. Checked cooling now that outdoor unit is running it is dropping temp in home.

Near Singer Rd, Abingdon, MD 21009
Clay K.

Clay K.

Found and repaired very small leak at TXV by-pass, changed air ranger air filter, old one was very dirty, customer should have air duct system cleaned.

Near Airdrie Ave, Abingdon, MD 21009
Clay K.

Clay K.

Follow up from 4-23-19, leak check, system was out of coolant, pressure test with dry nitrogen to 375 psi, and shut off service valves, today the house side only had 150 psi and the outdoor system had more pressure than that, when service valves were opened the house pressure increased, leak is on the house side, vacuum system and recharged with 7 lbs R410A (slight overcharge).

Near Airdrie Ave, Abingdon, MD 21009
Clay K.

Clay K.

No A/C 1st floor, new install, system out of coolant (94oz), checked all connections at outdoor system and indoor system, no oil trace found, also checled both coils, no leaks found, pressure test to 375 lbs dry nitrogen and shut ofoo service valves to isolate system, need to return to check for loss of pressure.

Near Airdrie Ave, Abingdon, MD 21009
Paul N.

Paul N.

Installed secondary drain trap and line on air handler.

Near Spruce Woods Ct, Abingdon, MD 21009
Clay K.

Clay K.

Club rejuvenation: Gas forced air furnace: Checked electrical connections and components. Tested voltage absourbtion system for blower, good. Took blower and inducer motor amp draws. Checked gas valve and safeties. Checked burner compartment and tubes. Checked start up and shut down of unit. Homeowner recently has basement remodeled. Recommend duct cleaning.

Near Airdrie Ave, Abingdon, MD 21009
John A.

John A.

Free Estimate on new Oil Boiler.

Near Old Joppa Rd, Abingdon, MD 21085
Steve M.

Steve M.

Giving a free estiment on a Heat Pump central home heating and air conditioning system